Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 720
Filtrar
1.
J Dent ; 145: 104989, 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38582435

RESUMEN

OBJECTIVE: To map and summarize the current scientific evidence concerning the active ingredients, effectiveness, and adverse effects of over-the-counter (OTC) bleaching products. DATA AND SOURCE: This study was conducted according to the PRISMA-ScR guidelines for scoping reviews and registered on the Open Science Framework platform. STUDY SELECTION: Database searches were conducted in PubMed/MEDLINE, Embase, and Scopus up to January 2024. All in vitro, in situ, and clinical studies evaluating the effectiveness and adverse effects of OTC bleaching products were included. A descriptive analysis of the included studies was performed. RESULTS: A total of 88 studies were included. Most of them were in vitro studies (n = 49), followed by randomized clinical trials (n = 28). The main OTC bleaching products identified were whitening or stain-removing toothpastes (n = 42), followed by whitening strips (n = 39). Most clinical studies indicate that whitening strips are effective in improving tooth color and providing whitening benefits. In contrast, the bleaching effectiveness of toothpastes, mouth rinses and whitening trays was mainly supported by in vitro studies. The main adverse effects associated with OTC bleaching agents were tooth sensitivity and gingival irritation. CONCLUSION: A wide variety of OTC bleaching products is available for consumer self-administered use. Clinical studies have mainly confirmed the bleaching effectiveness of whitening strips, while the validation for toothpastes, mouth rinses and whitening trays has mainly relied on in vitro studies. Nevertheless, the use of OTC bleaching products may result in adverse effects, including tooth sensitivity, gingival irritation, and enamel surface changes. CLINICAL SIGNIFICANCE: Some over-the-counter bleaching products may have whitening properties supported by clinical studies, particularly those containing hydrogen or carbamide peroxide. Nonetheless, clinicians must be aware of the potential risks associated with excessive self-administration of these products, which may result in adverse effects.

2.
Clin Oral Investig ; 28(4): 224, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38509406

RESUMEN

OBJECTIVES: To evaluate the bleaching efficacy and permeability of hydrogen peroxide (HP) in the pulp chamber of human teeth bleached with lower concentrations of carbamide peroxide gel (4%, 5% and 7% CP). MATERIALS AND METHODS: Bleaching gels with lower concentrations were formulated and a commercial standard gel, 10% CP, was used as a reference. Fifty-six human premolars were randomly divided into four groups. Applications of the bleaching gel were made for 3 h for 21 days. The bleaching efficacy was evaluated by digital spectrophotometry on 1, 7, 14 and 21 days, with analysis in the ∆Eab, ∆E00 and WID color spaces. The concentration of HP in the pulp chamber was measured in the same periods by UV-Vis spectrophotometry (µg/mL). Two-way repeated analysis of variance (ANOVA) examined bleaching efficacy and HP permeability, followed by Tukey's post-hoc test (α = 0.05). RESULTS: All groups showed significant color changes, with no statistical differences after the second and third week of bleaching (p > 0.05). The 'time' factor was statistically different (p < 0.05), increasing the bleaching efficacy throughout the treatment. The 4% CP group had lower HP levels in the pulp chamber (p < 0.05). CONCLUSIONS: The results seem promising, revealing that low concentration gels are as effective as 10% CP with the benefit of reducing the amount of HP in the pulp chamber. CLINICAL RELEVANCE: Low concentration 4% PC and 5% PC maintains bleaching efficacy, reduces the penetration of HP peroxide into the pulp chamber, and may reduce tooth sensitivity.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Peróxido de Carbamida , Cavidad Pulpar , Blanqueadores Dentales/farmacología , Peróxido de Hidrógeno , Blanqueamiento de Dientes/métodos , Ácido Hipocloroso , Geles , Urea/farmacología , Peróxidos/farmacología
3.
Arch Oral Biol ; 161: 105937, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38442471

RESUMEN

OBJECTIVE: To evaluate the role of induced nitric oxide synthase (iNOS) in nociception/orofacial discomfort in rats submitted to tooth whitening with hydrogen peroxide (H2O2). DESIGN: Wistar rats were divided into three groups (n = 24/group): a sham group not submitted to whitening treatment, a saline group submitted to whitening treatment, and a test group submitted to whitening treatment and blockade of iNOS with aminoguanidine 50 mg/kg/day. After 24 and 48 h, and 7 days, the animals were euthanized to collect trigeminal ganglia and maxillae to histomorphometric analysis (size of neuronal bodies and percentage of pulp area filled by vessels) and behavior/nociception (Grimace scales, scratching and biting counting, weight loss and nociception assay). ANOVA-1- or - 2-way tests were used (p < 0.05, GraphPadPrism 5.0). RESULTS: The aminoguanidine-treated group showed a reduction in nociceptive threshold in the masseteric region (p < 0.001), Grimace scale scores (p < 0.001), number of scratching (p = 0.011) and body mass loss (p = 0.007). After 24 and 48 h of tooth bleaching, the saline group showed a significant increase in the mean area of the blood vessels (p = 0.020) and iNOS immunostaining in odontoblasts (p = 0.002) and non-odontoblasts cells (p = 0.025). Aminoguanidine reversed both increases. Tooth bleaching reduced the mean area of neuronal bodies, and aminoguanidine significantly reversed it (p = 0.019), but an increase in GFAP immunostaining in neuronal bodies did not reduce after seven-days or after aminoguanidine treatment (p = 0.003). CONCLUSION: iNOS blockage by aminoguanidine plays an important role in nociception and orofacial discomfort by control of inflammation in dental pulp after tooth bleaching with hydrogen peroxide (H2O2) 35%.


Asunto(s)
Guanidinas , Blanqueadores Dentales , Blanqueamiento de Dientes , Ratas , Animales , Peróxido de Hidrógeno/farmacología , Nocicepción , Óxido Nítrico , Ratas Wistar , Óxido Nítrico Sintasa
4.
J Esthet Restor Dent ; 2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38475979

RESUMEN

OBJECTIVES: Evaluate the bleaching efficacy (BE) and tooth sensitivity (TS) of in-office bleaching using different application tips. METHODS: Forty-eight participants were selected (split-mouth), one to receive bleaching with an attached brush tip and one with a conventional tip. The procedure was performed with Whiteness Automixx Plus 35%. The BE was evaluated at the beginning, weekly, one and 12 months post-bleaching with a Vita Easyshade spectrophotometer (ΔE*ab , ΔE00 , and WID ) and with Vita classical A1-D4 and Vita Bleachedguide shade guides units (ΔSGU). Absolute risk and intensity of TS were recorded using the Visual Analogue Scale. The equivalence of BE was analyzed using the two one-sided t-tests for paired samples. The absolute risk of TS was evaluated using the McNemar test, and the TS intensity was measured with the paired t test (α = 0.05). RESULTS: The equivalence of BE was observed for both groups in all color evaluations (p > 0.05). A lower absolute risk and intensity of TS were observed for the attached brush tip when compared with the conventional tip (p < 0.003 and p < 0.0001). CONCLUSION: Using an attached brush tip showed the same BE as a conventional tip. However, for the attached brush tip, there was a reduction in TS. CLINICAL SIGNIFICANCE: The applicator-attached brush tip is recommended for in-office dental bleaching, because of the possible reduction in risk and intensity of TS.

5.
Clin Oral Investig ; 28(3): 189, 2024 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-38430338

RESUMEN

OBJECTIVES: To assess color change efficacy and the adverse effects of varied over-the-counter (OTC) bleaching protocols. METHODOLOGY: The study included randomized clinical trials evaluating color changes from OTC bleaching agents. Nine databases were searched, including the partial capture of the grey literature. The RoB2 tool analyzed the individual risk of bias in the studies. Frequentist network meta-analyses compared treatments through common comparators (∆Eab* and ∆SGU color changes, and tooth sensitivity), integrating direct and indirect estimates and using the mean and risk differences as effect measures with respective 95% confidence intervals. The GRADE approach assessed the certainty of the evidence. RESULTS: Overall, 37 remaining studies constituted the qualitative analysis, and ten composed the meta-analyses. The total sample included 1,932 individuals. ∆Eab* was significantly higher in groups 6% hydrogen peroxide (HP) strips (≥ 14 h). ∆SGU was significantly higher in groups at-home 10% carbamide peroxide (CP) (≥ 14 h), followed by 6% HP strips (≥ 14 h) and 3% HP strips (≥ 14 h). At-home 10% CP (7-13 h) and placebo showed lower risks of tooth sensitivity without significant differences between these treatments. CONCLUSION: Considering the low level of evidence, OTC products presented satisfactory short-term effects on tooth bleaching compared to the placebo, with little to no impact on dentin hypersensitivity and gingival irritation. CLINICAL RELEVANCE: OTC products are proving to be practical alternatives for tooth whitening. However, patients should be advised about the possible risks of carrying out such procedures without professional supervision.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Peróxido de Carbamida , Color , Sensibilidad de la Dentina/tratamiento farmacológico , Peróxido de Hidrógeno , Ácido Hipocloroso , Metaanálisis en Red , Medicamentos sin Prescripción/efectos adversos , Peróxidos , Blanqueamiento de Dientes/efectos adversos , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/efectos adversos , Blanqueadores Dentales/farmacología , Urea
6.
J Dent ; 143: 104902, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432352

RESUMEN

OBJECTIVE: To investigate the effect of tooth whitening on biomechanical properties of vacuum-formed retainers (VFRs). METHODS: Using a split-mouth, randomised controlled trial design, thirty participants were randomly allocated to receive whitening on either the upper or the lower arch, using 10 % carbamide peroxide for two weeks. Biomechanical properties such as hardness, tensile strength, and surface roughness were assessed two weeks after whitening was completed. RESULTS: Tensile strength of the whitening arch (mean ± SD: 40.93 ± 3.96 MPa) was significantly lower than that of the control (47.40 ± 5.03 MPa) (difference 6.47 MPa, 95 % CI 4.51 - 8.42, p < 0.001). Hardness and internal roughness of the whitening arch (VHN = 14.63 ± 2.29 N/mm2 and Ra = 1.33 ± 0.35 µm, respectively) were significantly greater than those of the control (12.22 ± 1.86 N/mm2 and 0.96 ± 0.29 µm, respectively) (differences 2.41 N/mm2, 95 % CI 1.56 - 3.25, p < 0.001 and 0.37 µm, 95 % CI 0.23 - 0.51, p < 0.001, respectively). The whitening arch showed greater tooth colour change (ΔE = 6.00 ± 3.32) than the control (ΔE = 2.50 ± 1.70) (difference = 3.50, 95 % CI 2.43 - 4.56, p < 0.001). CONCLUSIONS: Based on this short-term study, marked tooth colour change was achieved by whitening with VFRs as the whitening trays, but this changed the VFRs' biomechanical properties, including a decrease in tensile strength and an increase in hardness and internal roughness. CLINICAL SIGNIFICANCE: The application of carbamide peroxide in VFRs may compromise their mechanical properties.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Diente , Humanos , Peróxido de Carbamida , Vacio , Blanqueadores Dentales/farmacología , Urea , Peróxidos/farmacología , Peróxido de Hidrógeno/farmacología , Combinación de Medicamentos
7.
J Mech Behav Biomed Mater ; 153: 106497, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38458078

RESUMEN

OBJECTIVE: To evaluate whether coating enamel with a polymeric primer (PPol) containing titanium tetrafluoride (TiF4) before applying a bleaching gel with 35% H2O2 (35% BG) increases esthetic efficacy, prevents changes in morphology and hardness of enamel, as well as reduces the cytotoxicity from conventional in-office bleaching. MATERIALS AND METHODS: Standardized enamel/dentin discs were stained and bleached for 45 min (one session) with 35% BG. Groups 2TiF4, 6TiF4, and 10TiF4 received the gel on the enamel previously coated with PPol containing 2 mg/mL, 6 mg/mL, or 10 mg/mL, respectively. No treatment or application of 35% BG directly on enamel were used as negative control (NC), and positive control (PC), respectively. UV-reflectance spectrophotometry (CIE L*a*b* system, ΔE00, and ΔWI, n = 8) determined the bleaching efficacy of treatments. Enamel microhardness (Knoop, n = 8), morphology, and composition (SEM/EDS, n = 4) were also evaluated. Enamel/dentin discs adapted to artificial pulp chambers (n = 8) were used for trans-amelodentinal cytotoxicity tests. Following the treatments, the extracts (culture medium + bleaching gel components diffused through the discs) were collected and applied to odontoblast-like MDPC-23 cells, which were assessed concerning their viability (alamarBlue, n = 8; Live/Dead, n = 4), oxidative stress (n = 8), and morphology (SEM). The amount of H2O2 in the extracts was also determined (leuco crystal violet/peroxidase, n = 8). The numerical data underwent one-criterion variance analysis (one-way ANOVA), followed by Tukey's test, at a 5% significance level. RESULTS: Regarding the ΔE00, no difference was observed among groups 2TiF4, 6TiF4, and PC (p > 0.05). The ΔWI was similar between groups 2TiF4 and PC (p > 0.05). The ΔWI of group 6TiF4 was superior to PC (p < 0.05), and group 10TiF4 achieved the highest ΔE00 and ΔWI values (p < 0.05). Besides limiting enamel microstructural changes compared to PC, group 10TiF4 significantly increased the hardness of this mineralized dental tissue. The highest cellular viability occurred in 10TiF4 compared to the other bleached groups (p < 0.05). Trans-amelodentinal H2O2 diffusion decreased in groups 2TiF4, 6TiF4, and 10TiF4 in comparison with PC (p < 0.05). CONCLUSION: Coating enamel with a PPol containing TiF4 before applying a 35% BG may increase enamel microhardness and esthetic efficacy and reduce the trans-amelodentinal cytotoxicity of conventional in-office tooth bleaching. The PPol containing 10 mg/mL of TiF4 promoted the best outcomes.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Peróxido de Hidrógeno/química , Blanqueadores Dentales/farmacología , Dentina , Blanqueamiento de Dientes/efectos adversos , Esmalte Dental
8.
J Dent ; 142: 104875, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38309571

RESUMEN

OBJECTIVE: The application of anti-inflammatories as topical desensitizers before dental bleaching is an approach to reduce bleaching-induced tooth sensitivity (TS). This randomized controlled trial compared the risk and intensity of TS and the color change resulting from in-office dental bleaching after using an experimental desensitizing gel containing ibuprofen and arginine. METHODS: Sixty-two participants with upper canine shades A2 or darker were randomly assigned to either the ibuprofen-arginine desensitizing group or the placebo group. The desensitizing gel was applied for 15 min before in-office bleaching with 35 % hydrogen peroxide gel for 50 min (2 sessions). To assess the absolute risk and intensity of TS, visual (0-10) and numeric rating (0-5) scales were used, and group comparisons were made using the McNemar test, Wilcoxon test, and paired Student t-test (α = 0.05). Color change was evaluated using Vita Classical, Vita Bleachedguide (ΔSGU), and Vita EasyShade (ΔEab, ΔE00, and ΔWID) before and one month after the bleaching procedure. Group comparisons for color change were done using a paired t-test (α = 0.05). RESULTS: The odds ratio for TS was 0.14 [95 % CI 0.02 to 0.6], meaning lower odds of TS for the desensitizing gel. A lower intensity of TS was also observed for the experimental group (p < 0.005) up to 48 h after bleaching. All color evaluation tools demonstrated effective and similar whitening for both groups (p > 0.05). CONCLUSIONS: Using the experimental desensitizing gel containing ibuprofen and arginine effectively reduced the risk and intensity of TS without compromising the bleaching efficacy. CLINICAL RELEVANCE: The topical application of ibuprofen/arginine on the in-office bleaching reduced risk and intensity of bleaching-induced tooth sensitivity.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Humanos , Sensibilidad de la Dentina/inducido químicamente , Sensibilidad de la Dentina/prevención & control , Blanqueadores Dentales/efectos adversos , Ibuprofeno/uso terapéutico , Blanqueamiento de Dientes/efectos adversos , Blanqueamiento de Dientes/métodos , Peróxido de Hidrógeno/efectos adversos , Compuestos de Sodio , Arginina/uso terapéutico , Resultado del Tratamiento
9.
J Dent ; 143: 104880, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38336019

RESUMEN

OBJECTIVE: To evaluate the influence of antioxidants (ATX) resveratrol, winter's bark, green tea and yerba mate on the bond strength between bleached enamel and the nanohybrid composite resin. METHODOLOGY: Bovine incisor crowns (n = 132) were randomly divided into 22 groups (n = 6) according to the application times (5, 10, 15, 30, and 60 min) of each antioxidant. Teeth restored without previous bleaching or ATX constituted the non-bleached control group (NB Ctrl) (n = 6), and teeth restored after bleaching and without ATX represented the bleached control group (B Ctrl) (n = 6). The 35 % hydrogen peroxide was applied for 45 min (3 application of 15 min) to the buccal enamel surface. ATX was used after bleaching for the specified time of each group and removed with air-water spray. The enamel was etched with 37 % phosphoric acid (30 s) and rinsed with air-water spray. The adhesive resin was applied to the enamel dry surface. Teeth were restored using 1 mm composite resin increments (10 × 10 × 3 mm) and sectioned in test specimens of 6 mm in length and 1 mm2 in cross-sectional area submitted to microtensile bond strength test (0.5 mm/min). The load (N) at failure was recorded, and the bond strength (σt) was calculated (MPa). The fracture area was analyzed under optical microscopy, and failures were classified as cohesive, mixed, or adhesive. Data was evaluated by Kruskal-Wallis and Dunn tests (p ≤ 0.05). RESULTS: B Ctrl group presented lower σt than NB Ctrl (p < 0.001). Applying resveratrol for 5 or 10 min, winter's bark for 10 or 15 min, green tea for less than 15 min, and yerba mate for 15 min provided similar σt between bleached enamel and nanohybrid composite to the control group. CONCLUSION: Restorative procedures performed immediately after tooth bleaching compromises adhesion. Experimental antioxidants applied to bleached enamel can increase the immediate bond strength of restorations performed directly after bleaching, with similar values to those observed in unbleached enamel. CLINICAL SIGNIFICANCE: This study presents promising results to support the use of antioxidants on the recently bleached enamel to allow adhesive tooth restorations. The immediate bonding obtained using antioxidants was similar to the one achieved in non-bleached enamel in brief application times. Green tea extract and resveratrol were able to restore the bond strength to bleached enamel in a short application time of 5 min. The reduction in the required application time holds the potential to decrease the overall duration of the clinical section, offering clinical advantages and improving the feasibility of using antioxidants on the bleached enamel prior to adhesive procedures.


Asunto(s)
Antiinfecciosos , Recubrimiento Dental Adhesivo , Blanqueamiento de Dientes , Animales , Bovinos , Antioxidantes/farmacología , Antioxidantes/química , Resveratrol/farmacología , Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/farmacología , Cementos Dentales/química , Blanqueamiento de Dientes/métodos , Resinas Compuestas/farmacología , Resinas Compuestas/química , Esmalte Dental , Antiinfecciosos/farmacología , , Agua , Resistencia al Corte
10.
Odontology ; 2024 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-38367067

RESUMEN

The aim of this in vitro study was to evaluate the efficiency of diode laser-activated bleaching systems for color change of teeth. 75 extracted teeth were studied in five different bleaching protocols. Group 1: diode laser 445 nm, 320 µm fiber, 0.5W, continuous wave mode, dose 53 J/cm2. Group 2: diode laser 970 nm, 320 µm fiber, 1W, continuous wave mode, dose 106.10 J/cm2. Group 3: diode laser 940 nm, bleaching handpiece, 7W, continuous wave mode, dose 105 J/cm2. Group 4: diode laser 940 nm, 300 µm fiber, 2W, continuous wave mode, dose 47.16 J/cm2. Group 5: bleaching process without laser activation. In groups 1, 2 and 5, teeth were bleached with Perfect Bleach Office + and in groups 3 and 4, LaserWhite20 bleaching gel was used. Tooth color was determined immediately after the bleaching process using a spectrophotometer. Color change data on the CIE L * a * b* system was analyzed statistically by the one-way ANOVA and Tukey's HSD test. All bleaching procedures resulted in a change of color. All laser groups (∆E * ab > 3) have statistically larger ∆E * ab values than the control group (∆E * ab = 0.73) (p < 0.05). The diode laser 445 nm has the largest ∆E * ab value (∆E * ab = 4.65) and results in a significantly higher color difference than all other groups. In terms of color score difference in VITA Shades, all laser-activated groups lead to a lightening effect while the control group leads to only a slight lightening effect. The diode laser 445 nm produced the greatest color difference. Laser-activated bleaching is more effective than conventional bleaching without light activation. The diode laser 445 nm performs best in this in vitro study.

11.
Heliyon ; 10(3): e25833, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38371984

RESUMEN

Objectives: The objective of this umbrella review is to evaluate the efficacy and adverse effects of different teeth whitening techniques in-office (IO) and at-home (AH), regarding chromatic changes and teeth sensitivity. Materials and methods: The search was carried out from several databases. The included studies were all systematic reviews with or without meta-analysis of RCT or quasi-RCT. The participants were patients that underwent external dental bleaching in permanent vital teeth. The interventions were in-office (IO) bleaching techniques and at-home (AT) bleaching techniques with different bleaching agents and concentrations. Results: The search resulted in a total of 257 articles, and 28 SR were included in the qualitative analysis and nine in the quantitative analysis. There is no difference between in-office and at-home techniques in terms of color change (p = 0.95) and post-treatment sensitivity (p = 0.85). There is similarity risk and intensity of teeth sensitivity between AH and IO bleaching. IO bleaching with light-activated systems with low concentrations of bleaching agent showed similar results to IO bleaching techniques with high concentrated bleaching gels. With the application of the criteria of the AMSTAR 2 tool, the reviews were considered critically low to high. Conclusions: There are no significant differences in terms of color change between the different bleaching techniques compared. Teeth sensitivity is always present regardless of the technique used. The use of light activation systems did not increase the intensity and risk of post-operative sensitivity.

12.
J Esthet Restor Dent ; 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38353378

RESUMEN

OBJECTIVE: Assess color alteration and hydrogen peroxide (HP) penetration in human and bovine teeth using various in-office bleaching protocols with different application times. MATERIALS AND METHODS: Thirty healthy human premolars and 30 healthy bovine incisors were divided into five groups and subjected to different bleaching protocols: 2 × 15 min, 1 × 30 min, 2 × 20 min, or 1 × 40 min, with a control group for each tooth type. All teeth were treated with 35% HP gel. Color alteration was measured using digital spectrophotometry before and 1 week after bleaching. HP concentration within the pulp was determined via UV-Vis spectrophotometry. Statistical analysis included one-way ANOVA, Tukey's, and Dunnett's tests (α = 0.05). RESULTS: All groups exhibited significant color alteration, with no statistically differences among them (p > 0.05). However, significant differences were observed when compared with their respective control groups (p < 0.05). HP penetration into the pulp was evident in all bleached teeth compared to the control groups (p < 0.05), with the 2 × 20 group showing the highest HP levels within the pulp cavity, irrespective of tooth type (p < 0.05). CONCLUSION: A simplified 1 × 30-min protocol can be recommended as it effectively maintains color alteration and HP penetration, irrespective of whether human or bovine teeth. CLINICAL SIGNIFICANCE: This study suggests that an in-office dental bleaching protocol using a 1 × 30-min session is recommended, as it ensures both effective color change and no increase in the amount of HP penetration.

13.
Bioengineering (Basel) ; 11(1)2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38247960

RESUMEN

To examined alkaline phosphatase enzyme (ALP) activity and the effects of incorporating it in the thickener solution of a hydrogen-peroxide-based bleaching gel containing calcium-polyphosphate (CaPP) on the orthophosphate (PO43-) levels, bleaching effectiveness, and enamel microhardness. ALP activity was assessed at different pH levels and H2O2 concentrations, and in H2O- and Tris-based thickeners. Circular dichroism (CD) was used to examine the ALP secondary structure in water-, Tris-, or H2O2-based mediums. The PO43- levels were evaluated in thickeners with and without ALP. Enamel/dentin specimens were allocated into the following groups: control (without bleaching); commercial (Whiteness-HP-Maxx); Exp-H (H2O-based); CaPP-H; ALP-H (CaPP+ALP); Exp-T (Tris-based); CaPP-T; and ALP-T (CaPP+ALP). Color changes (ΔE/ΔE00) and the bleaching index (ΔWID) were calculated, and surface (SMH) and cross-sectional microhardness (CSMH) were assessed. The two-way ANOVA and Tukey's post-hoc tests were used to compare ALP and PO43- levels; generalized linear models were used to examine: ΔE/ΔE00/SMH/CSMH; and Kruskal-Wallis and Dunn's tests were used for ΔWID (α = 5%). The ALP activity was higher at pH 9, lower in H2O2-based mediums, and similar in both thickeners. The CD-spectra indicated denaturation of the enzyme upon contact with H2O2. The PO43- levels were higher after incorporating ALP, and the ΔE/ΔE00/ΔWID were comparable among bleached groups. SMH was lower after bleaching in Exp-H, while CSMH was highest in ALP-T.

14.
Lasers Med Sci ; 39(1): 21, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38165503

RESUMEN

This in vitro experimental investigation aimed to evaluate the impact of the combined application of a nanofiber scaffold (NS), a polymeric catalyst primer (PCP) containing 10 mg/mL of heme peroxidase enzyme, and violet LED (LEDv) on the esthetic efficacy (EE), trans-amelodentinal cytotoxicity (TC), and procedural duration of conventional in-office bleaching therapy. To achieve this, 96 standardized enamel/dentin discs were individually placed in artificial pulp chambers. A 35% hydrogen peroxide (H2O2) bleaching gel was administered for 45, 30, or 15 min to the enamel, either previously coated with NS + PCP or left uncoated, followed by irradiation with LEDv for 15 min or no irradiation. The established groups were as follows: G1, negative control (no treatment); G2, 35% H2O2/45 min; G3, NS + PCP + LEDv; G4, NS + PCP + 35%H2O2/45 min + LEDv; G5, NS + PCP + 35%H2O2/30 min + LEDv; and G6, NS + PCP + 35%H2O2/15 min + LEDv. Extracts (culture medium + gel components diffused through the discs) were collected and applied to odontoblast-like MDPC-23 cells. EE (ΔE00 and ΔWI) and TC were assessed using ANOVA/Tukey analysis (p < 0.05). The EE analysis revealed no statistical differences between G6 and G2 (p > 0.05). Cells in G6 exhibited higher viability and lower oxidative stress compared to other bleached groups (p < 0.05). In conclusion, employing NS + PCP + LEDv to catalyze a 35%H2O2 bleaching gel applied for 15 min to the enamel resulted in successful esthetic improvements and reduced the cytotoxicity commonly linked with traditional in-office bleaching procedures.


Asunto(s)
Peróxido de Hidrógeno , Polímeros , Peróxido de Hidrógeno/farmacología , Biopolímeros , Catálisis , Medios de Cultivo
15.
BMC Oral Health ; 24(1): 139, 2024 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-38281911

RESUMEN

BACKGROUND: Light-cured resins are widely used as gingival barriers to protect the gums from highly concentrated peroxides used in tooth bleaching. The impact of barrier brand on clinical outcomes is typically considered negligible. However, there is limited evidence on the effects of different brands on operator experience, barrier adaptation, and patient comfort. OBJECTIVE: This clinical trial assessed the impact of four commercial gingival barrier brands (Opaldam, Topdam, Lysadam, and Maxdam) on operator perception, adaptation quality, and patient comfort. METHODS: Twenty-one undergraduate students placed gingival barriers in a randomized sequence using blinded syringes. Photographs of the barriers were taken from frontal and incisal perspectives. After bleaching procedures, operators rated handling features and safety using Likert scale forms. Two experienced evaluators independently assessed barrier adaptation quality on a scale from 1 (perfect) to 5 (unacceptable). The absolute risk of barrier-induced discomfort was recorded. Data were analyzed using Friedman and Chi-square tests (α = 0.05). RESULTS: Opaldam and Topdam received the highest scores in most handling features, except for removal, which was similar among all brands. No significant difference was observed in barrier adaptation quality between the evaluated brands. Discomforts were mainly reported in the upper dental arch, with Maxdam having the highest absolute risk (35% for this arch and 24% overall). CONCLUSIONS: This study suggests that gingival barrier brands can influence operator perception and patient comfort. Opaldam and Topdam were preferred by operators, but all brands demonstrated comparable adaptation quality. CLINICAL TRIAL REGISTRATION: The study was nested in a randomized clinical trial registered in the Brazilian Clinical Trials Registry under identification number RBR-9gtr9sc.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Diente , Humanos , Sensibilidad de la Dentina/inducido químicamente , Sensibilidad de la Dentina/prevención & control , Sensibilidad de la Dentina/tratamiento farmacológico , Peróxido de Hidrógeno , Comodidad del Paciente , Percepción , Blanqueamiento de Dientes/efectos adversos , Blanqueadores Dentales/efectos adversos , Resultado del Tratamiento
16.
Artículo en Inglés | MEDLINE | ID: mdl-38198430

RESUMEN

This study evaluated the impact of using calcium-hydroxide or the antioxidant agents on the bond strength of adhesive restorations to bleached dentin. Forty teeth were prepared and allocated into 8 groups according to the surface treatment after bleaching (application or not of calcium hydroxide, 10% sodium ascorbate and 5% sodium thiosulphate for 10min), and the time of final restoration (immediate or after 7-days). Sodium perborate with 20% hydrogen peroxide was applied for 3 weeks using a developed artificial pulp chamber, with replacement every week. Composite resin restoration was performed and microtensile test was performed. Then, specimens were analyzed using a stereomicroscope and SEM. Data was submitted to Kruskal-Wallis and Dunn tests (p<0.05). The bond strength of non-bleached teeth was similar to the groups restored after 7 days of bleaching (p<0.05). The lowest values of bond strength were showed by groups restored immediately after bleaching (p<0.05). In all groups, there was a considerable predominance of adhesive fractures. Delaying the final restoration of teeth submitted to nonvital bleaching for 7 days permits an increase in bond strength. The immediate restoration of bleached teeth after the use of 10% sodium ascorbate or 5% sodium thiosulfate for 10 minutes showed unsatisfactory results. Clinical relevance Irrespective of the dentin protocol applied before adhesion, a satisfactory and an unsatisfactory result of bond strength values will be obtained delaying the final restoration or immediately performing the final restoration, respectively. Therefore, after nonvital tooth bleaching, clinicians should always delay the final restoration for a minimum period of 7 days.

17.
Caries Res ; 58(1): 49-58, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38043513

RESUMEN

INTRODUCTION: This in vitro study aimed to evaluate the effect of three different chemical agents on stain removal and mineral uptake of artificial dentin caries (ADC) lesions treated with silver diamine fluoride (SDF). METHODS: Baseline L*a*b* values were determined in polished human permanent dentin blocks, and ADC lesions were induced with an acid gel for 1 week. Samples were assigned to four groups; in three groups, half of each sample received SDF (30% SDF for 3 min), while the other half received SDF followed by a bleaching treatment protocol (garlic extract, bentonite, or 35% hydrogen peroxide). The fourth group had one SDF-treated half and one half without SDF. Color changes (ΔE) were measured by spectrometry, and transversal microradiography was used to quantify integrated mineral loss (ΔZ) 24 h after treatment (SDF or SDF + bleaching). A two-way mixed ANOVA was applied to thirty percent. RESULTS: SDF application increased mineral uptake by ADC (p = 0.001). The type of chemical agent evaluated (p < 0.0001), time (p = 0.01), and their interaction (p < 0.0001) bleached the ADC treated with SDF. However, 35% hydrogen peroxide was the only compound with a bleaching effect (p < 0.001), without returning to baseline color. None of the compounds altered the mineral uptake effect of SDF (p = 0.30). CONCLUSION: This in vitro study showed mineral uptake effect in ACD within 24 h after SDF application and the ability of hydrogen peroxide to partially remove (reduction of 24%) the staining caused by SDF without affecting its mineral uptake effect.


Asunto(s)
Colorantes , Susceptibilidad a Caries Dentarias , Compuestos de Amonio Cuaternario , Compuestos de Plata , Humanos , Peróxido de Hidrógeno/farmacología , Minerales , Dentina/diagnóstico por imagen , Fluoruros Tópicos
18.
Eur J Oral Sci ; 132(1): e12958, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37853653

RESUMEN

This clinical trial investigated the effects of pre-application enamel moistening on the impact of a 37% carbamide peroxide whitener on tooth color changes and the influence of repositioning guide colors. Forty participants were randomly assigned to in-office tooth bleaching with either moistened enamel (experimental) or dry enamel (control). The whitener was applied for 45 min over two sessions. Tooth color was visually measured or assessed using a spectrophotometer with purple or green silicone guides. Tooth bleaching was assessed using CIE76 (ΔEab ) and CIEDE2000 (ΔE00 ) formulas and by whitening and bleaching index score changes. Moistening the enamel did not significantly affect tooth color. However, the guide color choice only impacted tooth color when measured instrumentally. At baseline, the green guide resulted in statistically significantly whiter teeth than the purple guide. Less pronounced differences in the b* coordinate between baseline and final measurements were found using the green guide. The green guide also produced lower ΔEab values and less change in indexes. In conclusion, moistening the enamel did not significantly impact tooth color changes. However, the repositioning guide color influenced the tooth bleaching measured instrumentally, except for ΔE00 .


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Decoloración de Dientes , Humanos , Blanqueamiento de Dientes/métodos , Peróxidos/farmacología , Blanqueadores Dentales/farmacología , Urea , Esmalte Dental , Color , Peróxido de Hidrógeno
19.
J Esthet Restor Dent ; 36(2): 402-409, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37681984

RESUMEN

OBJECTIVE: To evaluate the penetration of hydrogen peroxide (HP) into the pulp chamber and the color change of different bleaching varnishes in low concentrations used for at-home bleaching. MATERIALS AND METHODS: Ninety healthy premolars were used, randomly distributed into nine groups (n = 10) according to bleaching varnish (PL, PolaLuminate; VS, VivaStyle Paint On Plus; CA, Cavex Bite&White whitening pen and; AW AlignerWhite) and time (10 and 30 min), and a control group (no bleaching). The penetration of HP was evaluated by UV-Vis spectroscopy. To evaluate the color change (ΔEab , ΔE00 , ΔWID ) a digital spectrophotometer was used (α = 0.05). RESULTS: The AW group in 10 min and the control group showed similar and lower HP penetration in the pulp chamber when compared to the other groups (p = 0.003). Increasing the application time to 30 minutes elevated the amount of HP inside the pulp chamber for all groups (p = 0.003), except for PL (p > 0.05). When applied for 30 min all bleaching varnishes showed higher color change (ΔWID ) when compared to 10 min (p = 0.04). CONCLUSIONS: For all bleaching varnishes evaluated, PolaLuminate applied for 30 min showed lower penetration into the pulp chamber and higher bleaching effects. CLINICAL SIGNIFICANCE: The use of bleaching varnishes seems promising for teeth bleaching, but it varies according to user product and protocol.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Peróxido de Hidrógeno/farmacología , Cavidad Pulpar , Blanqueamiento de Dientes/métodos , Blanqueadores Dentales/farmacología , Espectrofotometría , Color
20.
J Esthet Restor Dent ; 36(3): 460-468, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37728145

RESUMEN

OBJECTIVE: This study aims to assess hydrogen peroxide (HP) penetration into the pulp chamber, color change (CC), physical-chemical properties, and material wastage (MW) and material used (MU) in mixing tips when using in-office bleaching gels with two different mixing tips. MATERIALS AND METHODS: Forty teeth were divided into five groups (n = 8) based on the bleaching gels used (Pola Office +37.5% [PO+] and Whiteness HP Automixx Plus 35% [AM+]) and the mixing tip types (T-Mixer and Helical). A negative control group was treated with ultra-purified water. HP concentration was measured using UV-Vis, and CC was evaluated with a digital spectrophotometer. Initial concentration, pH, and viscosity were measured through Titration, a Digital pH meter, and Rheometer, respectively. MW and MU were measured using a precise analytical balance. Statistical analysis included two-way ANOVA, Tukey's, and Dunnett's test (α = 0.05). RESULTS: A higher HP concentration was observed with PO+ with the Helical mixing tip in comparison with AM+ (p = 0.01). No significant differences in CC or MU were found for different mixing tips (p = 0.001). The T-mixer mixing tip resulted in significantly less MW (p < 0.00001) and improved mixture homogeneity and viscosity. CONCLUSIONS: Utilizing a T-mixer with self-mixing bleaching gels achieves comparable CC while reducing MW. Moreover, it decreases HP penetration when using PO+. CLINICAL SIGNIFICANCE: For the application of a self-mixing in-office bleaching gel, a T-mixer mixing tip should be recommended, as it reduces the penetration of hydrogen peroxide into the pulp chamber when using PO+, while also minimizing gel wastage.


Asunto(s)
Blanqueadores Dentales , Blanqueamiento de Dientes , Peróxido de Hidrógeno , Blanqueamiento de Dientes/métodos , Esmalte Dental , Geles , Color
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...